
Authentic Best resources for NS0-173 Test Engine Practice Exam
[2021] NS0-173 PDF Questions - Perfect Prospect To Go With RealVCE Practice Exam
NEW QUESTION 25
The storage administrator must change the vHBA settings bound to a template associated with a production server.
What happens when the settings are reconfigured in this scenario?
- A. The vHBA template is deleted from UCS Manager.
- B. The vHBA configuration change does not affect LUN access.
- C. The service profile template that is associated with the server is initialized.
- D. The server that is associated with the service profile reboots.
Answer: C
NEW QUESTION 26
A customer is planning to use a pair of MDS switches in a FlexPod design to host a few SAN workloads.
In this scenario, which two features should be enabled on the MDS switches for a successful configuration? (Choose two.)
- A. NPIV
- B. port-channel-trunk
- C. NPV
- D. fport-channel-trunk
Answer: A,B
NEW QUESTION 27
A customer has deployed a FlexPod Datacenter with Red Hat Enterprise Linux OpenStack Platform. The Cinder storage volumes that are attached to the Nova instances are not available.
Based on the terms of the cooperative support model, which three companies would the customer use to open a support case? (Choose three.)
- A. Cisco
- B. NetApp
- C. Red Hat
- D. VMware
- E. Microsoft
Answer: A,B,C
NEW QUESTION 28
After you install a FlexPod infrastructure at a customer site, you need to migrate the existing Vmware virtual machines off the infrastructure that was used before FlexPod was installed.
Which VMware vSphere feature accomplishes this task?
- A. vSphere HA
- B. vSphere DRS
- C. vMotion
- D. VM Component Protection
Answer: C
NEW QUESTION 29
Your customer has a FlexPod configuration with a 4-node NetApp AFF A300 storage cluster that uses only NSE drives.
Which two solutions allow the customer to expand the current storage system? (Choose two.)
- A. a DS4246 with twenty-four 6 TB NL-SAS HDDs
- B. a two-node FAS8200 with a 4 TB NL-SAS HDD
- C. a DS224C with twenty-four 3.8 TB SSDs
- D. a two-node AFF A200 with a 3.8 TB NSE SSD
Answer: B,C
NEW QUESTION 30
A customer is configuring the UCS to handle a multitenant environment. The customer has created an organization within UCS for each tenant and would like to allow access to these organizations for only users that belong to that tenant.
In this scenario, which feature in UCS Manager should the customer use to accomplish this task?
- A. User Roles
- B. Trusted Platform Module
- C. Service Profile
- D. Locales
Answer: C
NEW QUESTION 31
Which port type would you configure when you connect a chassis to the Cisco Fabric Interconnects?
- A. FC storage ports
- B. Ethernet uplink ports
- C. appliance ports
- D. server ports
Answer: A
NEW QUESTION 32
An administrator decides to connect storage directly to UCS Fabric Interconnect to support FCoE within a FlexPod configuration.
In this scenario, which port type should be defined on the Fabric Interconnect ports that are connected to the storage controller?
- A. uplink port
- B. appliance port
- C. server port
- D. monitor port
Answer: A
NEW QUESTION 33
A customer wants to design a FlexPod configuration based on a CVD that was published 10 months ago. The customer wants to ensure that they are using the latest hardware and software versions.
In this scenario, which two tools are used to identify the latest supported hardware and software? (Choose two.)
- A. Cisco UCS Hardware and Software Interoperability Matrix
- B. NetApp OnCommand System Manager
- C. NetApp Interoperability Matrix Tool
- D. Cisco UCS Director
Answer: A,D
Explanation:
C: When using this matrix to determine recommended driver versions for you server configuration, please reference the server's Blade/Rack Bundle firmware version for the recommended driver in the event that your servers are running Mixed Firmware from your Infrastructure Bundle.
D: Cisco UCS Director delivers unified, highly secure management for supported compute, network, storage, and virtualization platforms and for the industry's leading converged infrastructure solutions
NEW QUESTION 34
A customer is planning to deploy a FlexPod solution for a large scale SAN requirement that uses the FC protocol. The customer plans to use Smart Zoning in the configurations to reduce the number of TCAM entries in the zoning process.
In this scenario, which design would enable the customer to use Smart Zoning?
- A. storage connected to Cisco Nexus 9000 Series switches
- B. storage directly connected to Cisco UCS Fabric Interconnects
- C. storage connected to Cisco MDS switches
- D. storage connected to Cisco Nexus 5000 Series switches
Answer: C
NEW QUESTION 35
A service provider is designing a FlexPod configuration to host multiple customers in a hybrid cloud environment, where IP address-range conflicts might arise on the shared storage.
Which NetApp feature should be enabled to prevent these conflicts?
- A. IPspaces
- B. failover groups
- C. SVMs
- D. broadcast domains
Answer: A
NEW QUESTION 36
Which two Unified Computing System capabilities are required to achieve stateless computing? (Choose two.)
- A. service profiles
- B. blade servers
- C. boot from SAN
- D. templates
Answer: A,B
Explanation:
Cisco introduced the idea of stateless computing with its blade server design.
A Cisco UCS instance allows you to quickly align computing resources in the data center with rapidly changing business requirements. This built-in flexibility is determined by whether you choose to fully implement the stateless computing feature.
Pools of servers and other system resources can be applied as necessary to respond to workload fluctuations, support new applications, scale existing software and business services, and accommodate both scheduled and unscheduled downtime. Server identity can be abstracted into a mobile service profile that can be moved from server to server with minimal downtime and no need for additional network configuration.
NEW QUESTION 37
Which command would a FlexPod administrator use to determine whether an FC initiator has logged on to the fabric?
- A. MDS9148>show fcfwd
- B. MDS9148>show flogi database
- C. MDS9148>show fcdomain
- D. MDS9148>show fcc
Answer: B
NEW QUESTION 38
A client has a requirement to set up a FlexPod Datacenter with the NetApp fabric MetroCluster architecture. You want to enable connectivity between the deployments.
In this design, which two components are required to accomplish this task? (Choose two.)
- A. Cisco Nexus 3000 switches
- B. Cisco Nexus 7000 switches
- C. Cisco Nexus 9000 switches
- D. Cisco MDS 9300 switches
Answer: B,C
NEW QUESTION 39
A customer is evaluating management tools for a new FlexPod infrastructure. They desire a tool that can orchestrate the provisioning of UCS compute nodes, NetApp storage, and VMware networking.
Which tool satisfies the requirements of this customer's heterogeneous environment?
- A. NetApp OnCommand Unified Manager
- B. UCS Central
- C. UCS Director
- D. NetApp OnCommand Insight
Answer: C
NEW QUESTION 40
You are designing a FlexPod solution with a 2-node storage system, multiple compute chassis, and ACI.
In this scenario, which two network switches are required? (Choose two.)
- A. core switch
- B. spine switch
- C. leaf switch
- D. cluster interconnect switch
Answer: B,C
NEW QUESTION 41
You want to deploy a FlexPod Datacenter solution based on the minimum hardware requirements.
Which three components must be deployed in highly available pairs to accomplish this task? (Choose three.)
- A. Cisco UCS Fabric Interconnects
- B. NetApp FAS Storage Controllers
- C. Cisco USC Nexus Switches
- D. Cisco APICs
- E. Cisco UCS 5108 Chassis
Answer: A,B,E
NEW QUESTION 42
A customer wants to deploy a FlexPod solution that involves directly connecting the NetApp AFF storage using the FCoE protocol to the Cisco UCS Fabric Interconnects.
In this scenario, which Cisco UCS Fibre Channel mode would be used to accomplish this task?
- A. access mode
- B. switching mode
- C. end host mode
- D. trunk mode
Answer: B
NEW QUESTION 43
A customer has verified physical connectivity on the FlexPod. However, the LUNs are not available on the Cisco UCS server. To make the LUNs visible to the UCS, the customer must enable a switching feature for zoning.
In this scenario, what should the customer do?
- A. Enable NPIV on all switches.
- B. Enable Spine mode on all the Cisco Nexus 9000 switches.
- C. Enable NPV on all switches.
- D. Enable the device connector feature in Cisco UCS Manager.
Answer: D
NEW QUESTION 44
......
Best updated resource for NS0-173 Online Practice Exam: https://www.realvce.com/NS0-173_free-dumps.html