Online 5V0-21.21 Test Brain Dump Question and Test Engine [Q29-Q44]

Share

Online 5V0-21.21 Test Brain Dump Question and Test Engine

Real VMware 5V0-21.21 Exam Dumps with Correct 52 Questions and Answers


VMware 5V0-21.21 Exam Syllabus Topics:

TopicDetails
Topic 1
  • identify the tasks to manape a stretches vSAN cluster
  • Identify the operational tasks required to manape an encrypted vSAN
Topic 2
  • Given a scenario, identify the implications of integrating VMware solutions with vSAN
  • Given a scenario, identify the use cases for an HCI Mesh infrastructure
Topic 3
  • identify the appropriate action to troubleshoot performance issues in a vSAN deployment
  • Identify vSAN data placement changes (stretches clusters, fault aomains)
Topic 4
  • VMware Products and Solutions
  • Given a scenario, identify the VMware products and solutions that will interact with a vSAN solution
Topic 5
  • Given a scenario, identify the implications of integrating VMware solutions with vSAN
  • Installing, Configuring, ana Setup

 

NEW QUESTION 29
An organization has two vSAN clusters managed by the same vCenter Server, each providing 100TB of storage. The first cluster runs at 75% of its storage capacity, and the second cluster runs at 50% of its storage capacity.
The company also has the following:
* An iSCSI array of 300TB. which runs at 76% of its capacity
* A NAS system of 200TB, which runs at 10% of its capacity
* A Fiber channel (FC) array of 300TB, which runs at 80% of its capacity The administrator is asked to add an additional 25TB of storage to the first cluster. The administrator is also made aware that there is no budget to purchase new hardware and that the vSAN Storage Policy Based Management must be kept in place.
Which storage option will work for this use case?

  • A. Obtain additional free capacity from the existing NAS storage.
  • B. Create an HCI Mesh using the first cluster's datastore.
  • C. Obtain additional free capacity from the existing FC storage.
  • D. Create an HCI Mesh using the second cluster's datastore.

Answer: A

 

NEW QUESTION 30
A 30-minute power maintenance window has been approved on Sunday. Due to a delay, the maintenance took 20 minutes longer to finish.
During this time, the vSAN administrator noticed that one of the clusters nodes was affected by a power shortage, as it was connected to an affected power source. The default vSAN storage policy has been applied.
What will be the status of the vSAN objects on the affected host immediately after it is recovered?

  • A. All objects will remain accessible.
  • B. The cluster will be partitioned and the vSAN host will need to be rejoined.
  • C. A rebuild of the affected objects will occur.
  • D. All objects on the affected host will be lost.

Answer: C

 

NEW QUESTION 31
An architect collected the below technical requirements from the customer during a vSAN cluster design workshop:
* Maximize the vSAN datastore usable capacity.
* Deduplication and compression are required to help utilize available capacity efficiency.
* Ensure the highest level of resiliency wherever possible.
Which disk group configuration should the architect include in the design?

  • A. Two disk groups per host, each with one cache tier flash disk and four capacity tier flash disks.
  • B. Two disk groups per host, each with one cache tier flash disk and six capacity tier flash disks.
  • C. One disk group per host, with one cache tier flash disk and four capacity tier flash disks.
  • D. Two disk groups per host, each with one cache tier flash disk and six capacity tier magnetic disks.

Answer: D

 

NEW QUESTION 32
A company hosts a vSAN 7 stretched cluster for all development workloads. The original sizing of a maximum of 250 concurrent workloads in the vSAN cluster is no longer sufficient and needs to increase to at least 500 concurrent workloads within the next six months.
To meet this demand, the original 8-node (4-4-1) cluster has recently been expanded to 16 nodes (8-8-1).
Which three additional steps should the administrator take to support the current growth plans while minimizing the amount of resources required at the witness site? (Choose three.)

  • A. Deploy a new extra large vSAN witness appliance at the witness site.
  • B. Add the new vSAN witness appliance to vCenter Server.
  • C. Configure the new vSAN witness as a shared witness appliance.
  • D. Upgrade the vSAN stretched cluster to vSAN 7.0 U1.
  • E. Deploy a new large vSAN witness appliance at the witness site.
  • F. Configure the vSAN stretched cluster to use the new vSAN witness.

Answer: C,E,F

 

NEW QUESTION 33
An administrator wants to check the performance metrics for the workloads and their virtual disks that are running on a vSAN cluster, but no statistical charts are displayed in the vSphere client.
Why is this behavior being seen?

  • A. vSAN network diagnostic mode is not enabled.
  • B. vSAN performance verbose mode is not enabled.
  • C. vSAN proactive tests haven't been run yet.
  • D. vSAN performance service is turned off.

Answer: D

Explanation:
Some tools allow for measuring latency peaks. This unfortunately isn't ideal, as it can unfairly represent statistical outliers, which may very well occur when there is little to no I/O activity. The best way to understand the actual behavior of VM and application latencies is to observe in time based performance graphs. Depending on the level of detail, you may need to measure at the individual VMDK level. Become familiar with these graphs to determine what is normal, and what is not for that given application. This is where you can use built-in functionality of vCenter and the vSAN performance service metrics to gather this information.
Reference:
https://docs.vmware.com/en/VMware-vSphere/7.0/com.vmware.vsphere.vsan-monitoring.doc/GUID-EF27701E-7BAC-4E76-9D2F-E1C58CAAB06D.html

 

NEW QUESTION 34
An administrator managing a vSAN cluster of six-nodes with policy FTT-2/RAID-6 decided to put one of the nodes in maintenance mode using the "Full-data migration" option.
What will happen after this action is taken?

  • A. The system will prompt to add an additional host to the cluster in order to preserve the policy compliance.
  • B. The host will enter in maintenance mode and only data with no redundancy will remain accessible.
  • C. The host will enter into maintenance mode if both components of a certain object are residing on that host, then one of the components will be moved to another available host.
  • D. The host will enter in maintenance mode and the data will remain accessible until the host exits maintenance mode.

Answer: D

 

NEW QUESTION 35
Upon checking the latency goal under vSAN performance diagnostics, the vSAN Administrator sees this message displayed:
The increase in latency in the vSAN stack might be beyond expected limits.
Which two root causes can be identified to help remediate the issue? (Choose two.)

  • A. vSAN encryption is enabled
  • B. vSAN VMKemel portgroup is configured with the "Route based on IP hash" teaming policy
  • C. Incorrect sizing of the disk groups capacity disks
  • D. Large packet losses and retransmissions on the network layer
  • E. One or more disk groups are congested

Answer: D,E

 

NEW QUESTION 36
An administrator is tasked with preparing for a Cross vCenter migration in a stretched vSAN cluster where the virtual machines migration will be orchestrated via VMware Site Recovery Manager.
Which action should the administrator take so the migration is successful?

  • A. Reconfigure vCenter HA Admission control
  • B. Enable vCenter Single Sign-On Enhanced Linked Mode
  • C. Make sure that Witness traffic is on the management NIC.
  • D. Disable vSAN Deduplication and Compression

Answer: B

 

NEW QUESTION 37
multiple data centers, the customer relayed the following information:
* Highest possible mitigation during a host failure in terms of capacity.
* A constraint in this year's IT budget.
What should the architect recommend?

  • A. Enable performance services.
    A minimum cluster of 6 vSAN nodes.
  • B. Enable host build reserve.
    A minimum cluster of 4 vSAN nodes.
  • C. Enable IOInsight Metrics.
    A minimum cluster of 2 vSAN ROBO nodes.
  • D. Enable operations reserve.
    A minimum cluster of 3 vSAN nodes.

Answer: B

Explanation:
Performance services and IOinsight Metrics used for performance analysis. Operation reserve for internal VSAN operations. https://blogs.vmware.com/virtualblocks/2020/09/24/effective-capacity-management-with-vsan-7-update-1/

 

NEW QUESTION 38
An architect is working with an All-Flash vSAN configuration and will be using the Flash Caching Devices in vSAN.
Which requirement is specifically needed for these devices?

  • A. Write endurance
  • B. IOPS
  • C. Read endurance
  • D. Capacity

Answer: A

 

NEW QUESTION 39
An architect needs to automate an infrastructure that supports VMware Horizon as well as VMware Tanzu.
Which solution mandates the use of VMware vSAN?

  • A. VMware Horizon
  • B. VMware vRealize Automation
  • C. VMware Tanzu
  • D. VMware Cloud Foundation

Answer: B

 

NEW QUESTION 40
Due to the success of the recently deployed developer-only private cloud solution, a company has a new requirement to at least double the usable capacity in their all-flash vSAN cluster.
The vSAN cluster is deployed into a co-located datacenter that is owned by a third-party hosting company. The hosting company charges a fixed monthly cost for rack space and power consumption. The service owner has been given a limited budget for additional hardware purchases, but not for on-going co-location costs.
The current vSAN cluster has the following configuration:
* 10 vSAN Nodes with 2 CPUs (20 cores), 512 GB RAM
* 1 Disk Group per vSAN node
- 1 x 400 GB
- 4 x 1.8 TB
* De-duplication and Compression is enabled.
* vSAN Capacity is currently:
- Total: 72 TB
- Usable: ~40 TB (FTT1/RAID1) and ~60 TB (FTT1/RAID5).
As a result of any action taken, the service owner would like to ensure that overall availability of the vSAN cluster is increased.
Which two recommendations meet the requirement to increase capacity while maintaining service availability? (Choose two.)

  • A. Create a new Disk Group, and claim the newly installed cache and capacity SSD drives for each node.
  • B. Install an additional 400 GB SSD and 4 x 1.8 TB SSDs per vSAN node.
  • C. Update the existing Disk Group, and claim the newly installed drives for each node.
  • D. Replace existing SSDs with an 800 GB SSD and 4 x 3.8 TB SSDs per vSAN node.
  • E. Install an additional 3 x 1.8 TB SSDs per vSAN node.

Answer: A,E

 

NEW QUESTION 41
An administrator is tasked with setting up Kerberos authentication only for the vSAN File services.
Which version of Kerberos must be selected if the NFS version is v4.1?

  • A. krb4
  • B. krb5p
  • C. krb5
  • D. krb5i

Answer: D

 

NEW QUESTION 42
A customer is planning to deploy a vSAN cluster to host their in-house distributed ERP system. The hardware specifications for their server nodes include:
* 2 x Intel Xeon CPU E5-2697 v3 @ 2.60GHz
* 1TB memory
Which boot device is supported for the vSAN ESXi nodes for this customer?

  • A. A 4GB USB or SD device must be used.
  • B. ESXi Hosts must boot from a PMEM device.
  • C. A 16GB multiple-level cell (MLC) SATADOM device must be used.
  • D. A 16GB single-level cell (SLC) SATADOM device must be used.

Answer: C

 

NEW QUESTION 43
In a vSAN stretched cluster, which value must be set in the vSAN policy if there is no requirement for data mirroring across sites?

  • A. PFTT = 1
  • B. PFTT = 0
  • C. SFTT = 0
  • D. SFTT = 1

Answer: B

Explanation:
PFTT can be seen as "site failures", and you can always only tolerate 1 at most. SFTT can be seen as host failures, and you can define this between 0 and 3 https://www.yellow-bricks.com/2018/03/19/vsan-stretched-cluster-pftt-and-sftt-what-happens-when-a-full-site-fails-and-multiple-hosts-fail/

 

NEW QUESTION 44
......

Valid 5V0-21.21 Test Answers & VMware 5V0-21.21 Exam PDF: https://www.realvce.com/5V0-21.21_free-dumps.html

VMware 5V0-21.21 Certification Real 2022 Mock Exam: https://drive.google.com/open?id=1wcEJip3LH2idcJ7Daz9CR0HBTasUqLT_