SolarWinds Certified Professional Real Exam Questions and Answers FREE SCP-NPM Updated on Nov 09, 2023 [Q10-Q33]

Share

SolarWinds Certified Professional SCP-NPM Real Exam Questions and Answers FREE Updated on Nov 09, 2023

SCP-NPM Ultimate Study Guide - RealVCE

NEW QUESTION # 10
How can you add entities from NPM to monitor for all registered devices in your company domain?

  • A. Add each of your Domain Controllers as nodes to NPM and scan Active Directory Organization Units (OUs) for the registered devices
  • B. Add each registered device individually, and then select the entities you want to monitor
  • C. Select to query Domain Controllers in a Network Discovery and then select the Organizational Units (OUs) with the registered devices you want to scan
  • D. Use the NPM Active Directory Discovery tool to find all registered devices on the domain

Answer: A


NEW QUESTION # 11
You configure an alert to send you an email when you have a high CPU load on your devices. Your NPM web console shows several devices have high CPU utilization, but you have not received any emails. What could be the issue?

  • A. The hardware resources assigned to the system are too low
  • B. The alert threshold is set too high
  • C. The alerts are muted on the devices
  • D. SNMP is not configured on the devices

Answer: C


NEW QUESTION # 12
For any node you monitor, you can use Network Discovery to automatically add child volumes or interfaces for monitoring.

  • A. TRUE
  • B. FALSE

Answer: A


NEW QUESTION # 13
Which items can you display in Web Console maps?

  • A. Interfaces, volumes, and database instances
  • B. Monitored nodes, interfaces and volumes, SAM applications and components, and network links
  • C. Quarks, gluons, Leptons, nodes, and network links
  • D. Monitored nodes and network links

Answer: B


NEW QUESTION # 14
The finance department asks to view select reports from NPM. Because of compliance policies, you cannot create accounts in the Web Console for users outside of the IT department. How do you allow the finance department to view reports without a user account?

  • A. Create a DirectLink account in the Web Console
  • B. Enable the Link only option on the report
  • C. Create a service account for Finance
  • D. Enable the Guest account

Answer: C


NEW QUESTION # 15
You need to change the polling method from ICMP to SNMP on 200 nodes you monitor with Orion. How would you best accomplish this?

  • A. Bulk select nodes in Manage Nodes and change the polling method
  • B. Unmanage all the nodes and remanage them choosing SNMP as the polling method
  • C. Edit each individual node and change the polling method
  • D. Use the Orion Polling Configuration tool to change polling methods

Answer: D


NEW QUESTION # 16
All users can create their own Orion Maps. How do you limit a user from seeing or working with select monitored entities through the SolarWinds server?

  • A. Configure Account limitations to remove access to the Orion user account
  • B. Configure Alert imitations to remove access to the Orion user account
  • C. Unmanage entities to remove access to the Orion user account
  • D. Configure permissions on the monitored entity to remove access to the Orion user account

Answer: D


NEW QUESTION # 17
You can import device-specific MIBs into the SolarWinds MIB Database, but you cannot import UnDP pollers based on OIDs from device-specific MIBs.

  • A. False
  • B. True

Answer: A


NEW QUESTION # 18
You inherit an environment with NPM and begin to receive High Traffic Utilization alerts from interfaces. When you view the alert, the issue is resolved. How do you modify NPM to receive fewer false alerts?

  • A. Increase the status polling frequency on the problematic interfaces
  • B. Configure the alert so that it triggers only when traffic utilization remains high for a sustained period
  • C. Increase the statistics polling frequency on the problematic interfaces
  • D. Configure the alert so that it resets only when traffic utilization remains high for a sustained period

Answer: C


NEW QUESTION # 19
How many agents does NPM require for Quality of Experience, NetPath, and system monitoring on the same Windows server?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: D


NEW QUESTION # 20
What is the average resource consumption of an agent?

  • A. Between 1-2% CPU if the bandwidth is less than 8 KB/s
  • B. Less than 1% CPU, no storage because the agent is 1% in memory for faster access
  • C. Agents run as a virtual process and do not require local resources
  • D. Less than 1% CPU, max 1 MB of memory, 1 MB storage

Answer: D


NEW QUESTION # 21
Your team member cannot see any reports in the Orion Console. What can cause this issue?

  • A. The SQL server is on a different system than the SolarWinds server
  • B. The reports are configured with more than one limitation category
  • C. The Report Writer is not installed
  • D. The No Reports limitation is applied to the user account

Answer: D


NEW QUESTION # 22
Your network includes the headquarters and three remote sites. Users from remote site A complain they do not have access to the company's accounting server. Users from remote site B and C have access to the accounting server. How can you find the source of the issue?

  • A. Use NetPath to see if there are problem areas between remote site A and remote sites B and C
  • B. Verify that the accounting servers are up
  • C. Verify that the accounting servers' CPU utilization are not abnormally high
  • D. Use NetPath to see if there are problem areas between remote site A and the headquarters

Answer: D


NEW QUESTION # 23
You want to create a custom poller for a device. When you select the OID you get an "OID not supported" error. What does this mean?

  • A. Your firewall is blocking SNMP requests
  • B. The SNMP agent on the device does not report on this OID
  • C. The SNMP string that you used is incorrect
  • D. This OID requires the read/write community string

Answer: B


NEW QUESTION # 24
Which statistic should you use to determine peak network traffic?

  • A. Protocol distribution
  • B. Bandwidth usage
  • C. Packet loss
  • D. Network latency

Answer: B


NEW QUESTION # 25
Capacity planning is available for which metrics?

  • A. Hardware Health
  • B. Response Time, Interface, and Volume Utilization
  • C. Up/Down, Packet Loss, and Latency
  • D. CPU, Memory, and Interface

Answer: B


NEW QUESTION # 26
Which metrics can NPM monitor on an Ethernet switch? (Choose all that apply.)

  • A. Duplex mismatches
  • B. Buffer misses
  • C. Configuration changes
  • D. CPU utilization

Answer: A,B,C


NEW QUESTION # 27
How can you quickly generate a report in NPM to show the top 50 interfaces by percent utilization?

  • A. Copy a similar default report and edit it for the top 50 interfaces
  • B. Create a web-based report and filter the data to restrict to the top 50 interfaces
  • C. Create an advanced SQL query report
  • D. Copy a similar default report and edit it for different time-frames

Answer: A


NEW QUESTION # 28
You monitor three Cisco routers with NPM. NPM reports utilization statistics for two of the routers. NPM only shows Availability and Response Time statuses for the third router. Why do you not see utilization statistics on the third router?

  • A. The third node is monitored with the NPM agent
  • B. SNMP is not configured correctly on the third node
  • C. The third node is monitored with SNMP instead of ICMP
  • D. The third node is monitored with WMI instead of SNMP

Answer: B


NEW QUESTION # 29
You need to build an Orion Map to show the relationships and connections between your Cloud servers and on premise infrastructure. You add the nodes but discover that the Orion Platform is not automatically mapping the connection between your cloud server and on premise router. You have verified that layer 2 and layer 3 topologies are being polled on the devices. How do you resolve this issue?

  • A. You need to turn off layer 2 and layer 3 topology polling for cloud monitoring
  • B. You need to open the topology ports in your firewall between the on premise node and the cloud node
  • C. You cannot monitor the connection between on premise and off premise devices
  • D. You need to configure a custom connection between the cloud node and the on premise node

Answer: D


NEW QUESTION # 30
How many days of data must your database contain in order to see Capacity Forecast Charts in NPM?

  • A. 1 Day
  • B. 7 Days
  • C. 5 Days
  • D. 3 Days

Answer: B


NEW QUESTION # 31
Network performance over an inter-campus Ethernet link is slow. One side of the connection is experiencing a high number of packet drops. What information in NPM can you review to help discover the cause of the issue?

  • A. Routing tables on each side of the link
  • B. Possible Duplex Mismatches
  • C. Packet loss on the nodes on either side of the connection
  • D. MTU of each side of the link

Answer: B


NEW QUESTION # 32
How do you assign users access to select reports?

  • A. Use custom properties and account limitations to control report access
  • B. Save the reports in different sub-directories and set the permissions for each user
  • C. Configure the report and add a Report Limitation. Assign the limitation to users who need access to the report
  • D. Create the reports while logged in as each user and set permissions

Answer: C


NEW QUESTION # 33
......

Ultimate Guide to Prepare SCP-NPM Certification Exam for SolarWinds Certified Professional: https://www.realvce.com/SCP-NPM_free-dumps.html