100% Free NSE 6 Network Security Specialist NSE6_FSW-7.2 Dumps PDF Demo Cert Guide Cover [Q22-Q45]

Share

100% Free NSE 6 Network Security Specialist NSE6_FSW-7.2 Dumps PDF Demo Cert Guide Cover

PDF Exam Material 2024 Realistic NSE6_FSW-7.2 Dumps Questions


Fortinet is a leading provider of cybersecurity solutions that help organizations to secure their networks, endpoints, and cloud environments. One of the key products in their portfolio is FortiSwitch, a family of network switches that provide advanced threat protection and network segmentation capabilities. To help IT professionals validate their skills in using FortiSwitch, Fortinet offers the NSE6_FSW-7.2 certification exam.

 

NEW QUESTION # 22
Which two statements about managing a FortiSwitch stack on FortiGate are true? (Choose two.)

  • A. Only a hardware-based FortiGate can manage a FortiSwitch stack.
  • B. The switch controller feature must be enabled on FortiGate.
  • C. A FortiLink interface must be enabled on FortiGate.
  • D. FortiSwitch must be operating in standalone mode before authorization.

Answer: B,C


NEW QUESTION # 23
How are the 'by VLAN redirect MAC address quarantine' mode and the 'by redirect MAC address quarantine' mode on FortiGate similar?

  • A. Both modes move quarantined devices to the quarantine VLAN.
  • B. Both modes add quarantined device MAC addresses to the blocked firewall address group.
  • C. Both modes block intra-VLAN traffic by FortiGate automatically.
  • D. Both modes require firewall policies to block inter-VLAN traffic.

Answer: C


NEW QUESTION # 24
Refer to the diagnostic output:

What makes the use of the sniffer command on the FortiSwitch CLI unreliable on__port__23?

  • A. Just the port egress payloads are printed on CLI.
  • B. The types of packets captured is limited.
  • C. Only untagged VLAN traffic can be captured.
  • D. The switch port might be used as a trunk member

Answer: B


NEW QUESTION # 25
In which two ways can you assign a FortiSwitch port to a VDOM using multi-tenancy setup? (Choose two.)

  • A. Assign a port to a VDOM directly on the managed FortiSwitch.
  • B. Remove the managed FortiSwitch and allocate ports directly on FortiSwitch.
  • C. Create a virtual port pool on the FortiGate CLI.
  • D. Switch the FortiLink interface to the target VDOM.

Answer: A,C


NEW QUESTION # 26
Which is a requirement to enable SNMP v2c on a managed FortiSwitch?

  • A. Enable an SNMP v3 to handle traps messages with SNMP hosts.
  • B. Create an SNMP user to use for authentication and encryption.
  • C. Configure SNMP agent and communities.
  • D. Specify an SNMP host to send traps to.

Answer: C


NEW QUESTION # 27
Refer to the exhibit.

Core-1 and Access-1 are managed and authorized by FortiGate-1. which uses port4 as the FortiLink interface. After FortiGate authorizes and manages Core-2. Port1 status becomes STP discarding.
Why is port1 in the discarding state?

  • A. Core-2 has the lowest bridge priority.
  • B. Access-1 is the root bridge and can only have one root port.
  • C. Core-1 and Core-2 do not have MCLAG configuration.
  • D. port1 on Core-2 is discarding only management traffic.

Answer: C


NEW QUESTION # 28
Exhibit.

port24 is the only uplink port connected to the network where access to FortiSwitch management services is possible. However, FortiSwitch is still not accessible on the management interface. Which two actions should you take to fix the issue and access FortiSwitch? (Choose two.)

  • A. You must add VLAN ID 200 to the allowed VLANS on internal.
  • B. You must add port24 native VLAN as an allowed VLAN on internal.
  • C. You must allow VLAN ID 4094 on port24, if management traffic is tagged.
  • D. You should use VLAN ID 4094 as the native VLAN on port24.

Answer: C,D


NEW QUESTION # 29
Which statement about the configuration of VLANs on a managed FortiSwitch port is true?

  • A. Untagged VLANs must be part of the allowed VLANs: ingress and egress.
  • B. The native VLAN is implicitly part of the allowed VLAN on the port.
  • C. FortiSwitch VLAN interfaces are created only when FortiSwitch is managed by Forti-Gate.
  • D. Allowed VLANS expand the collision domain to the port.

Answer: B


NEW QUESTION # 30
Which interfaces on FortiSwitch send out FortiLink discovery frames by default in order to detect a FortiGate with an enabled FortiLink interface?

  • A. All ports have auto-discovery enabled by default.
  • B. No ports are enabled by default for auto-discovery. This must be configured under config switch interface.
  • C. The last four switch ports on FortiSwitch have auto-discovery enabled by default.
  • D. The ports with auto-discovery enabled by default are dependent upon the FortiSwitch model.

Answer: A


NEW QUESTION # 31
Which packet capture method allows FortiSwitch to capture traffic on trunks and management interfaces?

  • A. SPAN
  • B. Sniffer profile
  • C. TCP dump
  • D. sFlow

Answer: D


NEW QUESTION # 32
Refer to the exhibit.

The exhibit shows the current status of the ports on the managed FortiSwitch. Access-1.
Why would FortiGate display a serial number in the Native VLAN column associated with the port23 entry?

  • A. port23 is a member of a trunk that uses the Access-1 FortiSwitch serial number as the name of the trunk.
  • B. Ports connected to adjacent FortiSwitch devices show their serial number as the native VLAN.
  • C. A standalone switch with the shown serial number is connected on port23.
  • D. port23 is configured as the dedicated management interface.

Answer: C


NEW QUESTION # 33
Which QoS mechanism maps packets with specific CoS or DSCP markings to an egress queue?

  • A. Classification for ingress traffic
  • B. Marking for ingress traffic
  • C. Rate limiting for egress traffic
  • D. Queuing for egress traffic

Answer: A


NEW QUESTION # 34
Which LLDP-MED Type-Length-Values does FortiSwitch collect from endpoints to track network devices and determine their characteristics?

  • A. Power management
  • B. Inventory management
  • C. Location
  • D. Network policy

Answer: B


NEW QUESTION # 35
Exhibit.

LAG and MCLAG are used to increase the available network bandwidth and enable redundancy. How does spanning tree protocol see MCLAG and LAG if they are configured based on the physi-cal view shown in the exhibit? (Choose two)

  • A. Switch 1. Switch 2, and Switch 3 are seen as one MCLAG peer group
  • B. Switch 3 and Switch 4 uplinks are treated as single interfaces.
  • C. Switch 1 and Switch 2 both seen as one single switch.
  • D. Switch 3 and switch 4 are seen as one MCLAG switch client

Answer: C,D


NEW QUESTION # 36
Which statement about the use of the switch port analyzer (SPAN) packet capture method is true?

  • A. Traffic on the management interface can be mirrored and captured by the monitoring device.
  • B. The monitoring device must be connected to the same switch where the traffic is being mirrored
  • C. Mirrored traffic can be sent across multiple switches.
  • D. SPAN can be configured only on a standalone FortiSwitch.

Answer: A


NEW QUESTION # 37
Which feature should you enable to reduce the number or unwanted IGMP reports processed by the IGMP querier?

  • A. Enable the IGMP flood setting on the static port for all multicast groups.
  • B. Enable IGMP snooping proxy.
  • C. Enable IGMP flood unknown multicast traffic on the global setting.
  • D. Enable the IGMP flood reports setting on the mRouter port.

Answer: B


NEW QUESTION # 38
Exhibit.

Which configuration change will allow the managed FortiSwitch to accept SNMP requests from any source?

  • A. Add SNMP service on the management interface of the switch.
  • B. Configure an SNMP host to send SNMP traps.
  • C. Create a new local access profile for SNMP only.
  • D. Enable SNMP on the internal interface of the switch.

Answer: B


NEW QUESTION # 39
Which statement about the IGMP snooping querier when enabled on a VLAN is true?

  • A. The setting can only be enabled using the FortiSwitch CLI.
  • B. Active multicast receiver entries are aging on each IGMP query sent on the VLAN
  • C. All other indirectly connected switches will be unable to get IGMP multicast traffic.
  • D. IGMP reports on the VLAN are forwarded to all switch ports.

Answer: C


NEW QUESTION # 40
Which two types of Layer 3 interfaces can participate in dynamic routing on FortiSwitch? (Choose two.)

  • A. Switch virtual interfaces
  • B. Detected management interfaces
  • C. Physical interfaces
  • D. Loopback interfaces

Answer: A,D


NEW QUESTION # 41
What can an administrator do to maintain a FortiGate-compatible FortiSwitch configuration when changing the management mode from standalone to FortiLinK?

  • A. FortiGate automatically saves the existing FortiSwitch configuration during the FortiLink management process.
  • B. Use a migration tool based on Python script to convert the configuration.
  • C. Enable the FortiLink setting on FortiSwitch before the authorization process.
  • D. Register FortiSwitch to FortiSwitch Cloud to save a copy before managing with FortiGate.

Answer: D


NEW QUESTION # 42
Refer to the exhibit.

What two conclusions can be made regarding DHCP snooping configuration? (Choose two.)

  • A. Maximum value to accept clients DHCP request is configured as per DHCP server range.
  • B. Global configuration for DHCP snooping is set to forward DHCP client requests on all ports in the VLAN.
  • C. FortiSwitch is configured to trust DHCP replies coming on FortiLink interface.
  • D. DHCP clients that are trusted by DHCP snooping configured is only one.

Answer: C,D


NEW QUESTION # 43
FortiGate is unable to establish a tunnel with the FortiSwitch device it is supposed to manage Based on the debug output shown in the exhibit, what is the reason for the failure?

  • A. DTLS client hello had the incorrect pre-shared key.
  • B. The CAPWAP tunnel failed to come up due to a mismatch in time.
  • C. FortiSwitch has disabled FortiLink and is only managed as a standalone.
  • D. The handshake process timed out before FortiSwitch responded.

Answer: B


NEW QUESTION # 44
......


Fortinet NSE6_FSW-7.2 certification exam is recognized globally as a standard for network security skills and knowledge. It is an essential certification for individuals who want to work with FortiSwitch products and advance their careers in the field of cybersecurity. Fortinet NSE 6 - FortiSwitch 7.2 certification program is designed to provide candidates with the skills and knowledge necessary to design, implement, and manage network security solutions using FortiSwitch products.

 

Updated Fortinet NSE6_FSW-7.2 Dumps – PDF & Online Engine: https://www.realvce.com/NSE6_FSW-7.2_free-dumps.html

NSE6_FSW-7.2.pdf - Questions Answers PDF Sample Questions Reliable: https://drive.google.com/open?id=1eEJepQ8Y-tszJNLEntSOPEVkYBcY7EtL